Alimentations 12V,48V pour Switch industriel

Alimentations Industrielle 48VDC, montage sur rail DIN  puissance de 60watt, 75Watt, 120W, 240Watt

Product Description

Features:

•Universal AC input / Full range

•Protections:Short circuit / Overload / Over voltage / Over temperature

•Cooling by free air convection

•Can be installed on DIN rail TS-35/7.5 or 15

•LED indicator for power on

•100% full load burn-in test

•Fix switching frequency at 50KHz

SPECIFICATION:

    MODEL

     DR-75-12

     DR-75-24

    OUTPUT

DC VOLTAGE

12V

24V

RATED CURRENT

6.3A

3.2A

CURRENT RANGE

0 ~ 6.3A

0 ~ 3.2A

RATED POWER

76W

76.8W

RIPPLE & NOISE (max.) Note.2

100mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

12 ~ 14V

24 ~ 28V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±1.0%

SETUP, RISE TIME

1000ms, 60ms/230VAC 1800ms, 60ms/115VAC at full load

HOLD UP TIME (Typ.)

60ms/230VAC 12ms/115VAC at full load

     INPUT

VOLTAGE RANGE

85 ~ 264VAC 120 ~ 370VDC

FREQUENCY RANGE

47 ~63Hz

EFFICIENCY (Typ.)

76%

80%

AC CURRENT (Typ.)

1.6A/115V 0.96A/230V

INRUSH CURRENT (Typ.)

COLD START 20A/115VAC 40A/230VAC

LEAKAGE CURRENT

<1mA/ 240VAC

 PROTECTION

OVERLOAD

105 ~ 150% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

15 ~ 16.5V

29 ~ 34V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

85°C+5°C (TSW1) detect on heat sink of power transistor

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.

-10 ~ +60°C (Refer to “Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-20 ~ +85”C, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 ~ 50°C)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

   SAFETY &

      EMC

   (Note 4)

SAFETY STANDARDS

UL508, TUV EN60950-1 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH

EMC EMISSION

Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A

   OTHERS

MTBF

123.1K hrs min. MIL-HDBK-217F (25°C)

DIMENSION

55.5*125.2*100mm (W*H*D)

PACKING

0.6Kg; 20pcs/13Kg/1.29CUFT

      NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

 

Features:

•Universal AC input/Full range

•Protections: Short circuit / Overload / Over voltage

•Cooling by free air convection

•Can be installed on DIN rail TS-35/7.5 or 15

•LED indicator for power on

•DC OK relay contact

•No load power consumptions.<0.75W

•100% full load burn-in test

SPECIFICATION:

 MODEL

     MDR-60-5

    MDR-60-12

   MDR-60-24

   MDR-60-48

   OUTPUT

DC VOLTAGE

5V

12V

24V

48V

RATED CURRENT

10A

5A

2.5A

1.25A

CURRENT RANGE

0 ~ 10A

0 ~5A

0 -2.5A

0-1.25A

RATED POWER

50W

60W

60W

60W

RIPPLE & NOISE (max.) Nota.2

80mVp-p

120mVp-p

150mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

5 -6V

12-15V

24 – 30V

48 ~ 56V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

LOAD REGULATION

±1.5%

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME Note.5

500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC 20ms/115VAC at full load

     INPUT

VOLTAGE RANGE

85 – 264VAC 120-370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

78%

86%

88%

87%

AC CURRENT (Typ.)

1.8A/115VAC 1A/230VAC

INRUSH CURRENT (Typ.)

COLD START 30A/115VAC,60A/230VAC

LEAKAGE CURRENT

<1mA/240VAC

 PROTECTION

OVERLOAD

105 – 150% rated output power

Protection type: Constant current limiting, recovers automatically after fault condition is removed

OVERVOLTAGE

6.25-7.25V

15.6 – 18V

31.2-36V

57.6 – 64.8V

Protection type: Shut down o/p voltage, re-power on to recover

FUNCTION

DC OK SIGNAL

Relay contact rating (max.): 30V/1A resistive

ENVIRONMENT

WORKING TEMP.

-20 – +70°C (Refer to “Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85°C, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 – 50°C)

VIBRATION

Component: 10 – 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

   SAFETY &

      EMC

   (Note 4)

SAFETY STANDARDS

UL508, UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE

l/P-0/P:3KVAC l/P-FG:2KVAC 0/P-FG:0.5KVAC

ISOLATION RESISTANCE

l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH

EMC EMISSION

Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3

EMC IMMUNITY

Compliance to EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A

    OTHERS

MTBF

299.2K hrs min. MIL-HDBK-217F (25°C)

DIMENSION

40*90*100mm (W*H*D)

PACKING

0.33Kg; 42pcs/14.8Kg/0.82CUFT

      NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.
  5. 5.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

TS-DR: Single Output DIN rail Power supply

TS-DR-75-48 75W Single Output DIN rail Power supply
TS-DR-120-48 120W Single Output DIN rail Power supply
TS-DR-240-48 240W Single Output DIN rail Power supply

 Features :

  • Universal AC input / Full range
  • Protections:Short circuit / Overload / Over
  • voltage / Over temperature
  • Cooling by free air convection
  • Can be installed on DIN rail
  • LED indicator for power on
  • 100% full load burn-in test
  • Fix switching frequency at 50KHz

SPECIFICATION :

Model

TS-DR-75-48

TS-DR-120-48

TS-DR-240-48

DC output voltage

48V

48V

48V

Rated output current

1.6A

2.5A

5A

Wave and noise

240mVp-p

100mVp-p

150mVp-p

Inlet wire stability

±0.5%

Load stability

±0.5%

Efficiency

81%

85%

Adjustable range for DC voltage

±10%

Input voltage range

85~264VAC 47~63Hz;120~370VDC

Impact current

Cold-start current 20A/115V 40A/230V

Cold-start current 27A/115V 45A/230V

Overload protection

105%~150% Type: cut off the output, automatic recovery

Over-voltage protection

120%~140% shutdown O/P voltage, re-power on to recover

55~60V

Setup, rise , hold up time

1000ms, 60ms, 60ms/230VAC at full load

500ms, 70ms, 30ms/230VAC at full load

800ms, 40ms, 20ms/230VAC at full load

Withstand voltage

I/P-O/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1 minute

Isolation resistance

I/P-O/P  I/P-FG  O/P-FG: 500VDC/100MΩ

Working temperature

-10°c~+50°c

Dimension

55.5×125.2×100mm

65.5 x 125.2 x 100mm

125.5 x 125.5 x 100mm

Weight

0.55kg

0.8kg

1.2kg

Packing

42 x 25 x 24CM/24PCS/13.5kg

45.5 x 35 x 26CM/24PCS/19.2kg

41.5 x 27.5 x 25CM/12PCS/14.5kg

Marque: Telesystem